How to configure the Groove Enterprise Management Server (EMS) to use a non-standard HTTP port
INTRODUCTION
This article describes how to configure the Groove
Enterprise Management Server (EMS) to use a non-standard HTTP port.
MORE INFORMATION
You can configure the Groove Enterprise Management Server
(EMS) to use a port other than the default HTTP port 80.
- If you have not manually created the EMS Web site in
Microsoft Internet Information Services (IIS), you can configure a custom port during the installation process. To do this, follow these steps:
- Follow the standard EMS installation directions through to the assignment of the Web site Information.
- In Web site Information, change the value from the default of 80 to the desired port number for the EMS Web site in the Web site TCP Port field.
- In the EMS Server URL field, modify
the value to include the nonstandard port number. The modified syntax should resemble the following:
http://hostname[:portnumber]/gms.dll
- If you manually created the EMS Web site under IIS in
advance of installing the EMS server, you cannot c hange these
values during the EMS installation. However, you can change these values after the EMS installation in IIS. To do this, follow these steps:
- Right-click the EMS Web site, and then click Properties.
- Click the Web Site tab, type the new port number in the TCP Port box, and then click OK.